Bizsafe L3
Profile > Air Filters Products > Laminar Air flow Services >Cabinets- Laminar Air Flow/Biosafety Cabinets > Contact Us > Project References

interfoldgi

IF30 Interfold Pleated Disposable 25-35% air filters
....................................................

ASHRAE 52.1-1992 Dust Spot Efficiency = 25-35%
EN779 Filter Grade: G4

Material: Non-woven Expanded GI reinforced cotton/poly fabric
Frame: US Kraft Board
Continuous Temperature: 70 deg cel
Final Pressure Drop: 250 Pa

Used as pre or primary filter for AHU and HVAC applications

Download technical specs in pdf version

Size: 24 x 24 x 1"
Filter Size: 595 x 595 x 22mm
Initial Pressure Drop: 95 Pa @ 3400 cmh

Size: 24 x 24 x 2"
Filter Size: 595 x 595 x 45mm
Initial Pressure Drop: 70 Pa @ 3400 cmh

Size: 24 x 24 x 4"
Filter Size: 595 x 595 x 95mm
Initial Pressure Drop: 50 Pa @ 3400 cmh

FC-GI-FGFI-Gi-FG-back

EM-GIringpanel

PPmesh

FC Al / Gi Frame with Synthetic Washable
EM Gi / Al Frame with Synthetic Washable
2DP / 4DP Gi Pleated Synthetic Washable

..............................................
Material: Synthetic Washable/ US mesh
Frame: GI / Al / SS
Continuous Temperature: 70 deg cel
Final Pressure Drop: 150 Pa

Flat panel are used as pre or primary filter for AHU and HVAC applications and fresh air applications.

PP Mesh with Gi rod
..............................................
Material: Polyprolyene Woven Mesh
Frame: Gi / SS Rod
Continuous Temperature: 70 deg cel
Final Pressure Drop: 75 Pa

Flat panel commonly used in ceiling cassette, fan coils units, fresh air intake or big dust particle removal applications. Resuable by washing.

Ring Panel with Synthetic Washable Media
..............................................
Material: 2 ply Synthetic Washable
Frame: Gi Rod with Ultrasonic Welded Seams
Continuous Temperature: 70 deg cel
Final Pressure Drop: 150 Pa

Flat panel used as pre or primary filter for Fresh Air, Intake Fans, AHU and HVAC applications. Ring panel can be reused several times by washing.

Download technical specs in pdf version

FC Frame
Various sizes up to 4" thick

EM Frame / 2DP & 4DP
Size: 24 x 24 x 1"
Filter Size: 595 x 595 x 22mm

Size: 24 x 24 x 2"
Filter Size: 595 x 595 x 45mm

PP mesh with Gi Rod
Various Sizes of about 5-6mm thickness

Ring Panel with Rod
Various Sizes of about 1" thick

if40

IF40 Interfold pleated Disposable 40-45%
.....................................
ASHRAE 52.1-1992 Dust Spot Efficiency = 35-45%
EN779 Filter Grade: F5

Material: Meltbown Synthetic
Frame: US Kraft Board
Continuous Temperature: 70 deg cel
Final Pressure Drop: 250 Pa

Higher medium efficiency filters used in AHU & HVAC applications.

Download technical specs in pdf version

Electrostatic Filter ES Pleated Merv11 Download technical specs in pdf version

Inter-Fold 40 1" filter is suitable for airflow more than 2000cmh or frontal velocity > 1.5m/s.

Size: 24 x 24 x 1"
Filter Size: 595 x 595 x 22mm
Initial Pressure Drop: 105Pa @ 2000 cmh

Size: 24 x 24 x 2"
Filter Size: 595 x 595 x 45mm
Initial Pressure Drop: 90Pa @ 3400 cmh

Size: 24 x 24 x 4"
Filter Size: 595 x 595 x 95mm
Initial Pressure Drop: 75Pa @ 3400 cmh

IF55 Interfold Pleated Disposable 50-55%
.....................................
ASHRAE 52.1-1992 Dust Spot Efficiency = 50-55%
EN779 Filter Grade: F5

Material: Meltbown Synthetic
Frame: US Kraft Board
Continuous Temperature: 70 deg cel
Final Pressure Drop: 250 Pa

Higher medium efficiency used in specialised allocated HVAC applications only, Available in high Capacity rated only.

Download technical specs in pdf version

Interfold 55 1" thickness filter is not recommended for use for high pressure drop. 2" filter is suitable for airflow less than 2000cmh or frontal velocity > 1.5m/s.

Size: 24 x 24 x 2"
Filter Size: 595 x 595 x 45mm
Initial Pressure Drop: 140 Pa @ 2000 cmh

Size: 24 x 24 x 4"
Filter Size: 595 x 595 x 95mm
Initial Pressure Drop: 150 Pa @ 3400 cmh

 

FGKB Interglass Fibreglass Kraftboard
.....................................
ASHRAE 52.76 Arrestance Efficiency = 85%
EN779 Filter Grade: G3

Material: Glassfibres
Frame: US Kraft Board
Continuous Temperature: 70 deg cel
Final Pressure Drop: 250 Pa

Fibreglass Filters used for removal of paint in spray paint booths and as paintstop arrestor as well as pre-filters in AHU or HVAC applications.

Download technical specs in pdf version

Media Thickness: 50mm

Size: 24 x 24 x 2"
Filter Size: 595 x 595 x 45 mm
Initial Pressure Drop: 30 Pa @ 3400 cmh

Please refer to fibreglass in synthetic rolls page.

 
   

Al mesh

Al-US-Mesh

 

Al Mesh / SS Mesh / Al US Mesh Grease Removal
.....................................
Grease Removal Efficiency: 97% @ 1.7m/s (350fpm)
Frame: Aluminium / Stainless Steel 304
Filter Material: Al, SS Mesh, US Al Mesh
Continuous Temperature: 150 deg cel
Final Pressure Drop: 150 Pa

Used as a grease removal or oil mist eliminator in kitchen exhaust and HVAC exhaust applications. Also used in HVAC dust removal.

Download technical specs in pdf version

Size: 24 x 24 x 1"
Filter Size: 595 x 595 x 22mm
Initial Pressure Drop: 18 Pa @ 3400 cmh

Size: 24 x 24 x 2"
Filter Size: 595 x 595 x 45 mm
Initial Pressure Drop: 25 Pa @ 3400 cmh

Al / SS Baffle Grease or Sand Removal
.....................................
Grease Removal Efficiency: 94% @ 1.7m/s (350fpm)
Frame: Aluminum / Stainless Steel 304
Continuous Temperature: 250 deg cel
Final Pressure Drop: 150 Pa

US mesh media is used as pre-filter in electronic cleaners and Equipment

Metal Netting media is as grease filter for kitchen and grease removal applications

Used as a grease/ sand removal in kitchen exhaust and HVAC exhaust applications. Oil are collected through the run-off of the channels.

Download technical specs in pdf version

Size: 24 x 24 x 2"
Filter Size: 595 x 595 x 45 mm
Initial Pressure Drop: 20 Pa @ 3400 cmh
 
Copyright Reserved 2007 by CLYDE-IFC (S) PTE LTD